Products Battery FabricationOven

Four-door Circular Vacuum Oven for Battery Making

Make : India
Model : Four-door Circular Vacuum Oven for Battery Making
Categories : Battery Fabrication,Oven

Vacuum oven equipped with stainless liner, independent relay control and accurate temperature control. Heated, vacuum pumping and nitrogen filling are controlled by buttons. In the middle, there is one φ3″×D630mm cantilever shaft which withstand 250kg material.

  • Description
  • Specifications

Vacuum oven equipped with stainless liner, independent relay control and accurate temperature control. Heated, vacuum pumping and nitrogen filling are controlled by buttons. In the middle, there is one φ3″×D630mm cantilever shaft which withstand 250kg material.

Key Features

● It adops pneumatic valve, vacuuming and nitrogen filling, which has high efficiency, saves personnel and has good product performance.

● 4 cylinders design, 5mm thick stainless steel inner tank, strong corrosion resistance, each one is controlled separated without affecting each other.

● It adopts 304 stainless steel heating tube coiled liner heating type, and the temperature is controlled evenly. 

● It is sealed with silicone rubber sealing strip, the door is made of 15mm thick tempered glass.

● The four circular oven is controlled separately, total drying time, cycle time and vacuum pressure can be set separately according to customer.

● Elastic double-layer glass door with overpressure protection.

● PID adjustable, small thermal inertia, good temperature control effect.

● The screen system adopts the centralized operation of the touch screen, which is convenient to operate and reliable to control.

Technical Parameters

Model
 
Working voltage
AC380V
Input voltage
30KW
Temperature
RT ~ 150°C adjustable
Inner liner dimension
Ф450mm×D600mm
Inner chamber temperature error
±3℃ (No load in vacuum state)
Heating time
The temperature rise from room temperature to 100 ℃ in no-load state is less than 40 minutes. The cell core temperature  stablization time is 110 minutes.
Main heating temperature control accuracy
Displayed temperature accuracy within<1℃
Main heating temperature rise control
The safety switch is set at 150 ℃ during heating.
Drying method
The heating tube surrounds the inner tank for heating
Vacuum degree
-0.1Mpa
Vacuum maintaining time
≥98% for 24 hours at-0.1MPA
Control method
PLC, relay control
Circulating air system
Including circulating air system, which can carry out process programming and realize automatic comtrol
Protection functions
Automatic overtemperature alarm;      
Power failure automatic protecion function
Dimension
L2050×W1240×H2010mm
Weight
≈1000kg

Career